222Usage guidelinesThis command is applicable only to outbound PVCs.Examples# Set the CLP flag value of ATM cells to 1. system-view[Sysname] traffic behavior database[Sysname-behavior-database] remark atm-clp 1reset atm interfaceUse reset atm interface to clear PVC statistics.Syntaxreset atm interface [ interface-type { interface-number | interface-number.subnumber } ]ViewsUser viewPredefined user rolesnetwork-adminParametersinterface-type { interface-number | interface-number.subnumber }: Clears statistics about all PVCs(including PVCs on the interface and PVCs of the PVC -groups) for the specified interface. Both ATMinterfaces and ATM subinterfaces are supported. If you do not specify an interface, this commandclears statistics about all PVCs for all interfaces.Usage guidelinesThis command clears statistics only about PVCs. To clear statistics about interfaces, use theresetcounters interface command.Examples# Clear statistics about all PVCs for the interface ATM 2/4/0. reset atm interface atm 2/4/0reset counters interface virtual-ethernetUse reset counters interface virtual-ethernet to clear VE interface statistics.Syntaxreset counters interface [ virtual-ethernet [ interface-number ] ]ViewsUser viewPredefined user rolesnetwork-adminParametersvirtual-ethernet: Clears the statistics for a VE interface.interface-number: Specifies a VE interface by its number.