Table 10. System x3690 X5 IMM error messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.v See Chapter 4, “Parts listing, System x3690 X5 Types 7147, 7148, 7149, and 7192,” on page 249 to determine which componentsare customer replaceable units (CRU) and which components are field replaceable units (FRU).v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained servicetechnician.Event ID Message Severity Description Action800b050a-1e83xxxx Non-redundant:Insufficient Resourcesfor [RedundancySetElementName] hasassertedError Cooling zone alert. Cooling zone 3 error:Replace fan 3.800b050a-1e84xxxx Non-redundant:Insufficient Resourcesfor [RedundancySetElementName] hasassertedError Cooling zone alert. Cooling zone 4 error:Replace fan 4.800b050a-1e85xxxx Non-redundant:Insufficient Resourcesfor [RedundancySetElementName] hasassertedError Cooling zone alert. Cooling zone 5 error:Replace fan 5.806f0007-0301xxxx806f0007-0302xxxxThe Processor CPU n Status has Failedwith IERR.(n = microprocessornumber)Error A processor failed -IERR condition hasoccurred.1. Make sure that thelatest levels of firmwareand device drivers areinstalled for all adaptersand standard devices,such as Ethernet, SCSI,and SAS.Important: Some clustersolutions requirespecific code levels orcoordinated codeupdates. If the device ispart of a clustersolution, verify that thelatest level of code issupported for thecluster solution beforeyou update the code.2. Update the firmware(UEFI and IMM) to thelatest level “Updatingthe firmware” on page397).3. Run the DSA programfor the hard disk drivesand other I/O devices.4. Reseat the adapter.5. Replace the adapter.6. (Trained servicetechnician only) Replacemicroprocessor n.7. (Trained servicetechnician only) Replacethe system board.(n = microprocessornumber)186 System x3690 X5 Types 7147, 7148, 7149, and 7192: Problem Determination and Service Guide