Table 10. System x3690 X5 IMM error messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.v See Chapter 4, “Parts listing, System x3690 X5 Types 7147, 7148, 7149, and 7192,” on page 249 to determine which componentsare customer replaceable units (CRU) and which components are field replaceable units (FRU).v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained servicetechnician.Event ID Message Severity Description Action806f0207-0301xxxx806f0207-0302xxxxThe Processor CPU n Status has Failedwith FRB1/BIST condition.(n =microprocessor number)Error A processor failed -FRB1/BISTcondition hasoccurred.1. Check for a serverfirmware update.Important: Some clustersolutions requirespecific code levels orcoordinated codeupdates. If the device ispart of a clustersolution, verify that thelatest level of code issupported for thecluster solution beforeyou update the code.2. Make sure that theinstalledmicroprocessors arecompatible with eachother (see “Replacing amicroprocessor and heatsink” on page 351 forinformation aboutmicroprocessorrequirements).3. (Trained servicetechnician only) Reseatmicroprocessor n.4. (Trained servicetechnician only) Replacemicroprocessor n.(n = microprocessornumber)806f050d-040Xxxxx Array[ComputerSystemElementName] is incritical condition.Warning Drive array is incritical condition.The drive array specified inthe error message (1-32) isin critical condition.Replace the drive.Chapter 3. Diagnostics 191