v Follow the suggested actions in the order in which they are listed in the Action column until the problem issolved.v See Chapter 4, “Parts listing, System x3690 X5 Types 7147, 7148, 7149, and 7192,” on page 249 to determinewhich components are customer replaceable units (CRU) and which components are field replaceable units(FRU).v If an action step is preceded by “(Trained service technician only),” that step must be performed only by atrained service technician.Error code Description Action0058008 DIMM failed memory test. 1. Check IBM support site for an applicable RETAINtip or firmware update that applies to thismemory error.2. Swap the affected DIMM with a DIMM of thesame size and type from a different memorychannel.3. Run the Setup utility to enable all the DIMMs.4. If the DIMM still fails on a different memorychannel, replace the DIMM.5. If the swapped DIMM fails on the original DIMMconnector, inspect the DIMM connector for debrisor damage. If the connector is damaged, (trainedtechnician only) replace the system board.00580A1 Invalid DIMM population for mirroringmode 1. If a fault LED is lit, resolve the failure.2. Install the DIMMs in the correct sequence (see“Replacing a memory module” on page 296).00580A4 Memory population changed.Information only. Memory has been added, moved,or changed.00580A5 Mirror failover completeInformation only. Memory redundancy has been lost.Check the event log for uncorrected DIMM failureevents.00580B0 Memory SMI LINK failure 1. Check IBM support site for an applicable RETAINtip or firmware update that applies to thismemory error.2. Check the DIMM connector or pins on the systemboard for damage.3. Check the microprocessor and microprocessorsocket for damage.4. Use the microprocessor installation tool to removeand replace a microprocessor.5. (Trained technician only) replace the systemboard.00580B1 Memory SMI LINK failover No action; information only.0068002 CMOS battery cleared. 1. Reseat the battery.2. Clear the CMOS memory (see Table 3 on page 22).3. Replace the following components one at a time,in the following order, restarting the server aftereach one:a. Batteryb. (Trained service technician only) Systemboard.42 System x3690 X5 Types 7147, 7148, 7149, and 7192: Problem Determination and Service Guide