Table 10. System x3690 X5 IMM error messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.v See Chapter 4, “Parts listing, System x3690 X5 Types 7147, 7148, 7149, and 7192,” on page 249 to determine which componentsare customer replaceable units (CRU) and which components are field replaceable units (FRU).v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained servicetechnician.Event ID Message Severity Description ActionSensor DIMM n Temp hastransitioned to critical from a lesssevere state.(n = DIMM number)Error A sensor haschanged to Criticalstate from a lesssevere state.1. Make sure that the fansare operating, that thereare no obstructions tothe airflow, that the airbaffles are in place andcorrectly installed, andthat the server cover isinstalled and completelyclosed.2. Make sure that ambienttemperature is withinthe specifications.3. If a fan has failed,complete the action fora fan failure.4. Replace DIMM n.(n = DIMM number)806f0823-2101xxxx Watchdog Timer interrupt occurredfor Watchdog.Info The IPMI WatchdogTimer has expired.A watchdoginterrupt hasoccurred.Information only; no actionis required.806f0a07-0301xxxx CPU1 is operating in a degradedstate.Info The processor isbeing throttled dueto thermal or powerconditions.1. Check the IMM eventlog for any fan orcooling related issues orpower related issues.2. Make sure that theairflow at the front andrear of the chassis is notobstructed and thatfillers are in place andcorrectly installed.3. Make sure that theroom temperature iswithin operatingspecifications.806f0a07-0302xxxx CPU2 is operating in a degradedstate.Info The processor isbeing throttled dueto thermal or powerconditions.1. Check the IMM eventlog for any fan orcooling related issues orpower related issues.2. Make sure that theairflow at the front andrear of the chassis is notobstructed and thatfillers are in place andcorrectly installed.3. Make sure that theroom temperature iswithin operatingspecifications.210 System x3690 X5 Types 7147, 7148, 7149, and 7192: Problem Determination and Service Guide