195REPEATER OPERATION■ Auto repeater function(USA version only)The USA version automatically activates the repeater settings(duplex, ON/OFF, duplex direction, tone encoder ON/OFF)when the operating frequency falls within or outside of thegeneral repeater output frequency range. The offset and re-peater tone frequencies are not changed by the auto repeaterfunction. Reset these frequencies, if necessary.q While pushing [YY] and [ZZ], turn the power ON to enter INI-TIAL SET MODE.w Push [YY] or [ZZ] several times until “RPt” appears.e Rotate [VOL] to select the desired condition.• “OF”— the auto repeater function is turned OFF;• “R1”— the auto repeater function activates for duplex only;• “R2”— the auto repeater function activates for duplex and tone.r Push [✱•ENT ] (or [D• CLR ]) to exit INITIAL SET MODE.• Frequency range and offset direction■ Repeater lockoutThis function helps prevent interference to other stations byinhibiting your transmission when a signal is received. Thetransceiver has two inhibiting conditions, repeater and busy.q While pushing [YY] and [ZZ], turn the power ON to enter INI-TIAL SET MODE.w Push [YY] or [ZZ] several times until “RLO” appears.e Rotate [VOL] to turn the repeater lockout function to “RP,”“bU” or OFF.• “RP”: Transmit is inhibited when a signal with un-matched sub-audible tone is received.• “bU”: Transmit is inhibited when a signal is received.r Push [✱•ENT ] (or [D• CLR ]) to exit INITIAL SET MODE.USING INITIAL SET MODEUSING INITIAL SET MODEFrequency range Duplex direction145.200–145.495 MHz “–” appears146.610–146.995 MHz147.000–147.395 MHz “+” appears442.000–444.995 MHz “+” appears447.000–449.995 MHz “–” appears5