SCAN RESUME METHODSWhen using Scan, it’s necessary to decide under whatcondition you want your transceiver to continue scanningafter detecting and stopping for a signal. You canchoose Time-operated Scan or Carrier-operated Scan.The default is Time-operated Scan.a Time-Operated ScanYour transceiver stops scanning after detecting asignal, remains there for approximately 5 seconds, andthen continues to scan even if the signal is stillpresent.m Carrier-Operated ScanYour transceiver stops scanning after detecting asignal and remains on the same frequency until thesignal drops out. There is a 2 second delay betweensignal drop-out and scan resumption to allow time forany responding stations to begin transmitting.36SELECTING THE SCAN RESUME METHODUsethefollowingproceduretoswitch yourtransceiverbetween Time-operated ScanandCarrier-operated Scan.1 Press [CALL]+ POWER ON to enter Menu Set-up.2 Turn the ENC/SQL control to select Menu No. 03.e The current Scan Resume status appears.e¢ The default is "TO" (time-operated scan).3 Press[CALL]toselecteither"TO"or"CO",4 Press any keyotherthan[CALL],[LAMP],or[MONI]to exitMenuSet-up.Note:Holding[MONI] downwhilescanninghaltsScanregardless whether Time-operatedorCarrier-operatedScanisselected.Resumescanning byreleasing[MONI].