Using the Solar Array Simulator 4Series E4360 User’s Guide 77Select the Pacing and Time IntervalData capture can be trigger-paced or a time-paced. Specify TRIGger toselect trigger-paced data capture, or TIMer to select time-paced datacapture. With time-paced data capture, you must also specify the timeinterval. The minimum time interval is 20 milliseconds. The maximuminterval is 65.535 seconds.Front Panel: SCPI Command:Not available. To select trigger-paced data capture:SENS:DLOG:CLOC TRIG,(@1)To select time-paced data capture:SENS:DLOG:CLOC TIM,(@1)To specify a time interval of 1 second:SENS:DLOG:TINT 1,(@1)Select the Trigger SourceNOTE An immediate trigger command over the bus will generate animmediate trigger regardless of the trigger source.Unless you are using the TRIG:DLOG command to trigger the output,select a trigger source from the following:Bus Selects GPIB device trigger, *TRG, or (Group Execute Trigger).DlogSelects an output channel’s datalog timer as the trigger source. specifies the channel.Pin Selects a pin on the external port connector as the trigger source. specifies the pin number. The selected pin must also beconfigured as a Trigger Input to be used as a trigger source (seeAppendix B).TransientSelects an output channel’s transient system as the trigger source. specifies the channel.Use the following commands to select a trigger source:Front Panel: SCPI Command:Not available. To select bus as the trigger source:TRIG:DLOG:SOUR BUS,(@1)To select a channel’s dwell output:TRIG:DLOG:SOUR DWEL,(@1)To select a pin as the trigger source:TRIG:DLOG:SOUR PIN,(@1)To select a transient channel:TRIG:DLOG:SOUR TRAN,(@1)Because data logging happens at event triggers, it is recommended touse hardwire triggers on the external digital port connector tosynchronize data logging on multiple units.