4-14 Configuring Your ServerServerOption Parameter Description Your SettingSystemManagement– System Management submenu isdisplayed.ConsoleRedirection– Console Redirection submenu isdisplayed.BMC LANConfiguration– BMC LAN Configuration submenu isdisplayed.Event LogConfiguration– Event Log Configuration submenu isdisplayed.Assert NMI onPERRDisabled[Enabled]Specify whether to support PCIPERR or not.Assert NMI onSERRDisabled[Enabled]Specify whether to support PCISERR or not.FRB-2 Policy Disable FRB2 TimerDisable BSPDo Not Disable BSP[Retry 3 Times]Set the FRB level 2 timer.Boot Monitoring [Disabled]5 Minutes10 minutes15 minutes20 minutes25 minutes30 minutes35 minutes40 minutes45 minutes50 minutes55 minutes60 minutesSpecify whether to enable or disablethe boot monitoring function onbooting, or select the time limit fortimeout.To use this function, install NECESMPRO Agent. Set this item to"Disabled" if the system is bootedfrom OS without installation of NECESMPRO Agent.Boot MonitoringPolicy[Retry 3 Times]Always ResetSpecify the processing at theoccurrence of timeout during bootmonitoring.If [Retry 3 times] is selected, thesystem is reset after the occurrenceof timeout and OS boot is retried upto three times.If [Always Reset] is selected, thesystem is reset after the occurrenceof timeout and OS boot is retriedrepeatedly.* If no service partition exists in thesystem, OS boot is retriedrepeatedly from the systempartition.Thermal Sensor Disabled[Enabled]Specify whether to enable or disablethe thermal sensor monitoringfunction. If a thermal error isdetected with this item being set to"Enabled", the system stops at theend of POST.