System administrator settings 201Pen priori-tyPen parameters can be defined in two ways:- In the plot data file- In the Remote Configuration File (RCF) or Océ Job Ticket(OJT)If pen priority is set to 'Language', the pen parameters defined inthe plot data file will be used. If pen priority is set to 'Setup', thepen parameters defined in the configuration file or the job ticketreceived with the plot will be used.PS no clip If 'PS no clip' is set to 'On' and the plot defines a Page Size (PS)value of WxH (Width and Height), the PS is not taken into ac-count. In that case, the plot may be bigger or smaller than the PS.EmulationtypeYou can use the 'Emulation type' option to determine the type ofprinter you want to emulate: HP650C or HP750C. The defaultemulation type is HP650C, which is compatible with older ma-chines. Differences occur in the default pen palette and the de-fault number of pens. If HP750C is selected, the default paletteis a gray level palette and compatible with HP750C.Line at-tributesIf the 'HP default' value is set, the Line Attributes instruction isfully emulated. All types of lines ends/joins allowed by the Lineattributes specifications will be therefore printed according tothese specifications. For backward compatibility reasons, the in-terpretation of this instruction can be disabled ('Océ Round val-ue). In that case, the lines of the plot will be processed as roundedand without join.Pen widthscalingTo enable or disable the pen width scaling.If enabled: scaling an image will scale the pen width correspond-ingly.HPGL-2