88Running Sequence Tour SequenceThe following functions are available only if a TourSequence has been previously established through theAdministration Console. As described on the setup, any ofthe tours can be assigned to any of the monitors.1. Select the desired monitor.Refer to the Monitor Selection.2. Select the desired Tour Sequence Number by pressingthe numeric keys.3. Pressing the [FWD RUN] key while holding down the[TOUR SEQ] key will run the tour sequence in forwarddirection on the active monitor, or pressing the [REVRUN] key while holding down the [TOUR SEQ] key willrun the tour sequence in reverse direction on the activemonitor.The selected Tour Sequence Number (T8) with “R” sign(indicate running status) is displayed on the activemonitor.Note: By the factory default setting, pressing the[TOUR SEQ] key after numeric input will run theselected Tour Sequence forward.4. Press the [PAUSE] key to pause a Tour Sequence thatis being run on the active monitor.The “P” sign (indicating the pause status) is displayedat the Tour Sequence Number on the active monitor.5. Press the [FWD RUN] key to restart a Tour Sequenceforward from the next step that was previously pausedby pressing the PAUSE key.6. Press the [REV RUN] key to restart a Tour Sequencebackward from the next step that was previouslypaused by pressing the PAUSE key.7. Press the [NEXT] key to move the sequence one frameto the next step (in forward or reverse run direction)from the step that was previously paused by pressingthe PAUSE key.8. Press the [PREV] key to move the sequence one frameto the previous step (in forward or reverse run direc-tion) from the step that was previously paused bypressing the PAUSE key.9. To return to Spot monitoring, press the [STOP] key toend a Tour Sequence that is being run on the activemonitor. Call Group PresetThe following function is available only if a Group Presethas been previously established through the AdministrationConsole.1. As described earlier, a Group Preset determines whichmonitor is to be assigned to which camera. Therefore,selecting a monitor is not required.2. Select a desired Group Preset Number by pressing theNumeric keys.3. Press the [GROUP PRESET] key to activate a selectedGroup Preset function.The selected preset position of the cameras is dis-played on the assigned monitors at a time.INFORMATIONEntry:8INFORMATIONSeq 8 Fwd RunCAM IDVLD ST&DALM S GENSYS S(ALARM)087MSTATUSVLD HALLALM HBLK59642 31SHIFTCLEAR(ESC)EXITGROUPPRESETPREVS-CTL IDOPE IDNEXTGROUPSEQ PAUSE STOPTOURSEQ R E VRU N F W DRU NOSDVERMONITORLOCKOSD SERVICEINFORMATIONSeq 8 PauseINFORMATIONEntry:13INFORMATIONGroup Preset 13CAM IDVLD ST&DALM SGENSYS S(ALARM)087MSTATUSVLD HALLALM HBLK59642 31SHIFTCLEAR(ESC)EXITGROUPPRESETPREVS-CTL IDOPE IDNEXTGROUPSEQ PAUSE STOPTOURSEQ R E VRU N F W DRU NOSDVERMONITORLOCKOSD SERVICE