Chapter 2: Commissioning Procedures 397. Press OK to display the Transducers foundmenu.8. If you have:• A Wind transducer, carry out the Windtransducer setup procedure below.• A Speed transducer, carry out the Speedcalibration on page 40.Wind transducer setupThe wind transducer setup procedures are used to:• Linearize the vane.• Align the vane.• Calibrate the wind speed.LinearizationTo linearize the wind vane:.1. With the Transducers found menu displayed(see Preliminary procedure on page 38), scrollto the Wind option.2. Press OK to select the Wind transducer setupmenu.3. Scroll to the Calibrate Vane option.4. Press OK to select the Calibrate Vane startscreen.5. Keeping the boat speed below 2 knots andobserving the screen, turn the boat in circles,then press OK to start the calibration.6. Observe the Calibrate Vane run screen and con-tinue turning the boat.• If the boat speed is too high during calibra-tion, a Slow down message is displayed. Ifthis happens, reduce your speed.• Calibration completes automatically.7. When calibration is complete, the Wind transducer setup menu is displayed.iD11174-1Transducers FoundDepthRaymarineSerial no.135260Press OK to selectiD11211-1Transducers foundWindRaymarineSerial no.176342Press OK to selectiD11212-1WindCalibrate VaneRaymarineSerial no.176342Press OK to selectiD11213-1Press OK to continueCalibrate VaneMove in a slow circle, below 2kts.Watch for 'too fast' on display.