January 20072-183WorkCentre 7132 012-302 (A-Finisher), 012-903 (A-Finisher)Status-indicator-rapsRevision012-302 (A-Finisher) Front Cover Interlock OPENBSD-ON:CH15.1The Front Cover Interlock Open was detected.Initial Actions• Check that the Top Cover can be opened and closed.• Check that the Finisher Front Interlock Switch is properly installed, not broken, and has noforeign object.• Power Off/ON.ProcedureCheck the following;• Front Cover installation• hinges for any damage• Finisher Top Cover Interlock Sensor for any damageThee above parts are OK.Y NRepair or replace any of the parts that are defected.Enter Component Control [012-302]. Open and close the Front Cover to turn On and Off theFinisher Front Interlock Switch. The display changes.Y NConnect the connections of P/J8702 and P/J8733. P/J8702 and P/J8733 are securelyconnected.Y NConnect P/J8702 and P/J8733 securely.Check for an open or short circuit between J8702 and J8733. The wires betweenJ8702 and J8733 are OK.Y NRepair the open or short circuit.Measure the voltage between Finisher PWB J8702-4 (+) and GND (-). Open and closethe Front Cover to turn On and Off the Finisher Front Interlock Switch. The voltagechanges.Y NReplace the Finisher Front Interlock Switch (PL 22.7).Check the wires and connectors for an intermittent open or short circuit. If the problemcontinues, replace the Finisher PWB (PL 22.7).Measure the voltage between Finisher PWB J8702-1 (+) and (-). The voltage is approx.+24VDC.Y NGo to Wirenet 7.2.38 A-Finisher +24VDC and check the +24VDC circuit.Check the wires and connectors for an intermittent open or short circuit. If the problem contin-ues, replace the Finisher PWB (PL 22.7).012-903 (A-Finisher) Paper Remains at Compiler ExitSensorBSD-ON:CH15.3• At Power On, the Compile Exit Sensor detected paper.• While the Main Motor was operating at initialization at Power On, the Compile Exit Sensordetected paper.• When the Cycle down operation at the end of a job was complete, the Compile Exit Sen-sor was On.Initial Actions• Check the power supply voltage at the customer site for a drop.• Check the Compile Exit Sensor is properly installed and free from foreign objects and thatthe actuator is not binding.• Power Off/ON.ProcedureCheck for paper remaining on the Compile Exit Sensor and how it is installed. The sensor isproperly installed with no paper left there.Y NRemove the remaining paper and reinstall the sensor properly.Run DC330[012-150].Enter Component Control [012-150]. Actuate the Compile Exit Sensor. The display changes.Y NCheck the connections of P/J8709 and P/J8728. P/J8709 and P/J8728 are securelyconnected.Y NConnect P/J8709 and P/J8728.Check for an open or short circuit between J8709 and J8728. The wires betweenJ8709 and J8728 are OK.Y NRepair the open or short circuit.Measure the voltage between Finisher PWB J8709-3 (+) and GND (-). The voltage isapprox.+5VDC.Y NGo to Wirenet 7.2.36 A-Finisher +5VDC and check the +5VDC circuit.Measure the voltage between Finisher PWB J8702-2 (+) and GND (-). Actuate the Com-pile Exit Sensor. The voltage changes.Y NReplace the Compile Exit Sensor (PL 22.5).Check the wires and connectors for an intermittent open or short circuit. If the problemcontinues, replace the Finisher PWB (PL 22.7).Check the wires and connectors for an intermittent open or short circuit. If the problem contin-ues, replace the Finisher PWB (PL 22.7).