January 20072-711WorkCentre 7132 092-310, 092-934Status-indicator-rapsRevision092-310 ADC Sensor RAPBSD-ON:9.4BThere is a failure in the ADC Sensor circuit.Initial ActionsReplace the Black (K), Yellow (Y), Magenta (M), and/or Cyan (C) toner if empty (PL 5.2).When NVM 752-094 is set to “1”, the NVM 752-121 needs to be cleared to “0”. When, NVM752-121 is cleared to “0”, NVM 752-094 will be automatically cleared to “0”. Then, the faultcode 092-310 can be cleared. For more information, go to GP 15.ProcedureCheck for an Image Quality Defect. An Image Quality Defect is present.Y NVerify the condition of the circuit between the ADC Sensor and MCU PWB. The circuitis free of damage.Y NRepair the circuit as required.Check the operating voltages between the ADC Sensor and the MCU PWB. The volt-ages are correct.Y NReplace the MCU PWB (PL 11.1).Replace the Sensor Bar Assembly (PL 11.1).The defect is Low Image Density or Uneven Density.Y NThe defect is BackgroundY NVerify the condition of the circuit between the ADC Sensor and MCU PWB. The cir-cuit is free of damage.Y NRepair the circuit as required.Check the operating voltages between the ADC Sensor and the MCU PWB. Thevoltages are correct.Y NReplace the MCU PWB (PL 11.1).Replace the Sensor Bar Assembly (PL 11.1).Go to IQ 6 to troubleshoot IOT background.Go to IQ 3 to troubleshoot Low Image Density or Uneven Density.092-934 Print Count RAPA run control error occurred counting prints.ProcedureIf several 092-934 faults are logged, replace the MCU PWB (PL 11.1).