January 20072-72 WorkCentre 7132005-139, 005-141RevisionStatus-indicator-rapsCheck the wire between J765 and J755 for an open circuit or a short circuit (BSD 5.5 Flag2). The wire between J765 and J755 is conducting without an open circuit or a shortcircuit.Y NRepair the open circuit or short circuit.Measure the voltage between the DADF PWB P755-1 (+) and GND (-), and betweenP755-6 (+) and GND (-) (BSD 5.5 Flag 2). The voltage is approx. +24VDC.Y NReplace the DADF PWB (PL 16.3).Replace the DADF Registration Motor (PL 16.9) If the problem persists, replace theDADF PWB (PL 16.3).Execute Component Control [005-072]. The Exit Nip Release Solenoid can be heard.Y NCheck the connections of P/J766 and P/J756. P/J766 and P/J756 are connected cor-rectly.Y NConnect P/J766 and P/J756.Check the wire between P756 and J766 for an open circuit or a short circuit (BSD 5.6 Flag2). The wire between P756 and J766 is conducting without an open circuit or ashort circuit.Y NRepair the open circuit or short circuit.Replace the Exit Nip Release Solenoid (PL 16.4) If the problem persists, replace theDADF PWB (PL 16.3).Replace the DADF PWB (PL 16.3).005-141 CVT Feed Sensor Off JamBSD-ON:5.4Pre-regi Sensor turns Off before Feed Sensor turns Off.ProcedureIf the problem occurs frequently, check if Multi-feed or Shingling feed/Slip at feed occurs.1. Check each Roll surface has contamination/foreign substance attached.2. Check each Roll surface has foreign substance attached.3. Check Torque Limiter works normally.4. Check each Motor works normally.5. Check each Roll feed force is within normal range6. Check the connectors and wires for damage.If all above are OK, replace Feed Sensor,(PL 16.9). If the problem continues, replace theNudger Motor (PL 16.5). If the problem persists, replace the DADF PWB (PL 16.3).A B