January 20072-65WorkCentre 7132 005-131Status-indicator-rapsRevision005-131 CVT Invert On Jam RAPBSD-ON:5.4/5.5After the Registration Sensor turned On during Invert operation, the Invert Sensor did not turnOn within the specified time.Initial Actions• Power Off than OnProcedureExecute Component Control [005-211]. Actuate the DADF Invert Sensor with paper. The dis-play changes.Y NCheck the connections of P/J780 and P/J761. P/J780 and P/J761 are connected cor-rectly.Y NConnect P/J780 and P/J761.Check the wire between J780 and J761 for an open circuit or a short circuit (BSD 5.4 Flag5/Flag 6). The wire between J780 and J761 is conducting without an open circuit ora short circuit.Y NRepair the open circuit or short circuit.Measure the voltage between the DADF PWB P761-9 (+) and GND (-) (BSD 5.4 Flag 6).The voltage is approx. +5VDC.Y NReplace the DADF PWB (PL 16.3).Measure the voltage between the DADF PWB P761-8 (+) and GND (-) (BSD 5.4 Flag 5).Actuate the DADF Invert Sensor with paper. The voltage changes.Y NReplace the DADF Invert Sensor (PL 16.7).Replace the DADF PWB (PL 16.3).Execute Component Control [005-026]. The DADF Registration Motor starts up.Y NCheck the connections of P/J765 and P/J755. P/J765 and P/J755 are connected cor-rectly.Y NConnect P/J765 and P/J755.Check the wire between J765 and J755 for an open circuit or a short circuit (BSD 5.5 Flag2). The wire between J765 and J755 is conducting without an open circuit or a shortcircuit.Y NRepair the open circuit or short circuit.Measure the voltage between the DADF PWB P755-1 (+) and GND (-), and betweenP755-6 (+) and GND (-) (BSD 5.5 Flag 2). The voltage is approx. +24VDC.Y NReplace the DADF PWB (PL 16.3).Replace the DADF Registration Motor (PL 16.9) If the problem persists, replace theDADF PWB (PL 16.3).Replace the DADF PWB (PL 16.3).AABB