Parameter List1111.7 d: Reference SettingsYASKAWA SIEPC71061753A GA500 Technical Manual 355No.(Hex.) Name Description Default(Range) Ref.d4-09(02B0)RUNUp/Down 2 Bias LowerLimit Sets the lower limit of the Up/Down 2 bias as a percentage of the Maximum OutputFrequency.Note:Parameter A1-02 [Control Method Selection] selects which parameter is themaximum output frequency.• A1-02 ≠ 8 [EZOLV]: E1-04 [Maximum Output Frequency]• A1-02 = 8: E9-02 [Maximum Speed]0.0%(-99.9 - 0.0%)552d4-10(02B6)Up/Down Freq LowerLimit Select Sets the lower frequency limit for the Up/Down function.0 : Greater of d2-02 or Analog1 : d2-020(0, 1)552d4-11(02B7)Bi-directional OutputSelection Sets the function that changes the frequency reference to a Bi-Directional internalfrequency reference.0 : Disable1 : Enabled0(0, 1)552d4-12(02B8)Stop Position GainSets the gain to adjust the stopping accuracy. Set this parameter when b1-03 = 9[Stopping Method Selection = Stop with Constant Distance].1.00(0.50 - 2.55)553◆ d6: Field Weakening /ForcingNo.(Hex.) Name Description Default(Range) Ref.d6-01(02A0)Field Weakening LevelSets the drive output voltage as a percentage of E1-05 [Maximum Output Voltage] whenH1-xx = 63 [Field Weakening] is activated.80%(0 - 100%)554d6-02(02A1)Field WeakeningFrequency Limit Sets the minimum output frequency to start field weakening.0.0 Hz(0.0 - 590.0 Hz)554d6-03(02A2)Field Forcing SelectionSets the field forcing function.0 : Disabled1 : Enabled0(0, 1)554d6-06(02A5)Field Forcing LimitSets the limit value for field forcing to increase the motor excitation current reference asa percentage of E2-03 [Motor No-Load Current]. Usually it is not necessary to changethis setting.400%(100 - 400%)554◆ d7: Offset FrequencyNo.(Hex.) Name Description Default(Range) Ref.d7-01(02B2)RUNOffset Frequency 1Uses H1-xx = 44 [MFDI Function Select = Add Offset Frequency 1 (d7-01)] as apercentage of the Maximum Output Frequency to add or subtract the set frequency to/from the frequency reference.Note:Parameter A1-02 [Control Method Selection] selects which parameter is themaximum output frequency.• A1-02 ≠ 8 [EZOLV]: E1-04 [Maximum Output Frequency]• A1-02 = 8: E9-02 [Maximum Speed]0.0%(-100.0 - +100.0%)555d7-02(02B3)RUNOffset Frequency 2Uses H1-xx = 45 [MFDI Function Select = Add Offset Frequency 2 (d7-02)] as apercentage of the Maximum Output Frequency to add or subtract the set frequency to/from the frequency reference.Note:Parameter A1-02 [Control Method Selection] selects which parameter is themaximum output frequency.• A1-02 ≠ 8 [EZOLV]: E1-04 [Maximum Output Frequency]• A1-02 = 8: E9-02 [Maximum Speed]0.0%(-100.0 - +100.0%)555d7-03(02B4)RUNOffset Frequency 3Uses H1-xx = 46 [MFDI Function Select = Add Offset Frequency 3 (d7-03)] as apercentage of the Maximum Output Frequency to add or subtract the set frequency to/from the frequency reference.Note:Parameter A1-02 [Control Method Selection] selects which parameter is themaximum output frequency.• A1-02 ≠ 8 [EZOLV]: E1-04 [Maximum Output Frequency]• A1-02 = 8: E9-02 [Maximum Speed]0.0%(-100.0 - +100.0%)555V/f OLV OLV/PMOLV/PM AOLV/PM EZOLVV/f OLV OLV/PMOLV/PM AOLV/PM EZOLVV/f OLV OLV/PMOLV/PM AOLV/PM EZOLVV/f OLV OLV/PMOLV/PM AOLV/PM EZOLVV/f OLV OLV/PMOLV/PM AOLV/PM EZOLVV/f OLV OLV/PMOLV/PM AOLV/PM EZOLVV/f OLV OLV/PMOLV/PM AOLV/PM EZOLVV/f OLV OLV/PMOLV/PM AOLV/PM EZOLVV/f OLV OLV/PMOLV/PM AOLV/PM EZOLVV/f OLV OLV/PMOLV/PM AOLV/PM EZOLVV/f OLV OLV/PMOLV/PM AOLV/PM EZOLV