11.10 H: Terminal Functions382 YASKAWA SIEPC71061753A GA500 Technical ManualSetting Value Function Description Ref.14 Torque CompensationEnters the torque compensation value if the motor rated torque is 100%.65115 General Torque LimitEnters the torque limit that is the same for all quadrants for forward, reverse, and regenerative operation if themotor rated torque is 100%.65116 Differential PIDFeedback Enters the PID differential feedback value if the full scale analog signal (10 V or 20 mA) is 100%.6511F Not UsedUse this setting for unused terminals or to use terminals in through mode.65230 DWEZ Analog Input 1Use with DriveWorksEZ. Refer to the DriveWorksEZ online manual for more information.65231 DWEZ Analog Input 2Use with DriveWorksEZ. Refer to the DriveWorksEZ online manual for more information.652◆ H4: Analog OutputsNo.(Hex.) Name Description Default(Range) Ref.H4-01(041D)Terminal AM AnalogOutput Select Sets the monitoring number to be output from the MFAO terminal AM.Set the x-xx part of the Ux-xx [Monitor]. For example, set H4-01 = 102 to monitor U1-02 [Output Frequency].102(000 - 999)653H4-02(041E)RUNTerminal AM AnalogOutput Gain Sets the gain of the monitor signal that is sent from MFAO terminal AM.Sets the analog signal output level from the terminal AM at 10 V or 20 mA as 100%when an output for monitoring items is 100%.100.0%(-999.9 - +999.9%)653H4-03(041F)RUNTerminal AM AnalogOutput Bias Sets the bias of the monitor signal that is sent from MFAO terminal AM.When an output for monitoring items is 0%, this parameter sets the analog signal outputlevel from the AM terminal at 10 V or 20 mA as 0%.0.0%(-999.9 - +999.9%)653H4-07(0423)Terminal AM SignalLevel Select Sets the MFAO terminal AM output signal level.Note:Make sure that you set jumper S5 on the control circuit terminal board when youchange these parameters.0 : 0-10V (LowLim=0)2 : 4 to 20 mA0(0, 2)653H4-20(0B53)Analog Power Monitor100% Level Sets the level at 10 V when U1-08 [Output Power] is set for analog output.0.00 kW(0.00 - 650.00 kW)654◆ H5: Modbus CommunicationNo.(Hex.) Name Description Default(Range) Ref.H5-01(0425)Drive Node AddressSets the communication slave address for drives.Note:• Restart the drive after changing the parameter setting.• Setting 0 will not let the drive respond to MEMOBUS/Modbus communications.1FH(0 - FFH)654H5-02(0426)Communication SpeedSelection Sets the communications speed for MEMOBUS/Modbus communications.Note:Restart the drive after changing the parameter setting.0 : 1200 bps1 : 2400 bps2 : 4800 bps3 : 9600 bps4 : 19200 bps5 : 38400 bps6 : 57600 bps7 : 76800 bps8 : 115200 bps3(0 - 8)654V/f OLV OLV/PMOLV/PM AOLV/PM EZOLVV/f OLV OLV/PMOLV/PM AOLV/PM EZOLVV/f OLV OLV/PMOLV/PM AOLV/PM EZOLVV/f OLV OLV/PMOLV/PM AOLV/PM EZOLVV/f OLV OLV/PMOLV/PM AOLV/PM EZOLVV/f OLV OLV/PMOLV/PM AOLV/PM EZOLVV/f OLV OLV/PMOLV/PM AOLV/PM EZOLVV/f OLV OLV/PMOLV/PM AOLV/PM EZOLVV/f OLV OLV/PMOLV/PM AOLV/PM EZOLVV/f OLV OLV/PMOLV/PM AOLV/PM EZOLVV/f OLV OLV/PMOLV/PM AOLV/PM EZOLVV/f OLV OLV/PMOLV/PM AOLV/PM EZOLVV/f OLV OLV/PMOLV/PM AOLV/PM EZOLV