Parameter List1111.21 Defaults by Drive Model and Duty Rating ND/HDYASKAWA SIEPC71061753A GA500 Technical Manual 43111.21 Defaults by Drive Model and Duty Rating ND/HDThe values for the parameters in these tables depend on the values for parameters o2-04 and C6-01. Changing thesettings for o2-04 and C6-01 will change the default settings.◆ Three-Phase 200 V ClassNo. *1 Name Unit Default- Drive Model - 2001 2002 2004 2006C6-01 Normal /Heavy DutySelection-HD ND HD ND HD ND HD ND0 1 0 1 0 1 0 1o2-04 Drive Model(KVA)SelectionHex. 60 61 62 63E2-11(E4-11, E5-02)Motor RatedPower kW 0.1 0.2 0.2 0.4 0.4 0.75 0.75 1.1b3-04V/f Gainduring SpeedSearch % 100 100 100 100 100 100 100 100b3-06SpeedEstimationCurrent Level1- 1 1 1 1 1 1 0.5 0.5b3-08 SpeedEstimationACR P Gain- 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5b3-26 DirectionDeterminationLevel- 1000 1000 1000 1000 1000 1000 1000 1000b8-03 Energy SavingFilter Time s 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5b8-04 Energy SavingCoefficientValue- 481.7 356.9 356.9 288.2 288.2 223.7 223.7 196.6C6-02CarrierFrequencySelection - 4 7 4 7 4 7 4 7E2-01(E4-01)Motor RatedCurrent (FLA) A 0.6 1.1 1.1 1.9 1.9 3.3 3.3 4.9E2-02(E4-02)Motor RatedSlip Hz 2.5 2.6 2.6 2.9 2.9 2.5 2.5 2.6E2-03(E4-03)Motor No-Load Current A 0.4 0.8 0.8 1.2 1.2 1.8 1.8 2.3E2-05(E4-05)Motor Line-to-LineResistance Ω 35.98 20.56 20.56 9.842 9.842 5.156 5.156 3.577E2-06(E4-06)MotorLeakageInductance % 21.6 20.1 20.1 18.2 18.2 13.8 13.8 18.5E2-10(E4-10)Motor IronLoss W 6 11 11 14 14 26 26 38E5-01 PM MotorCodeSelection- FFFF FFFF FFFF FFFF FFFF FFFF FFFF FFFFL2-02 Power LossRide ThroughTimes 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2L2-03MinimumBaseblockTime s 0.2 0.3 0.2 0.3 0.2 0.3 0.3 0.4L2-04Powerloss V/fRecoveryRamp Time s 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3L2-05 UndervoltageDetection Lvl(Uv1)- 190 190 190 190 190 190 190 190L3-02Stall PreventLevel duringAccel % 150 120 150 120 150 120 150 120