5.9 Absolute Encoders5-735 OperationSet the value, the desired rotational amount -1, to Pn205.5.9.7 Multiturn Limit Disagreement Alarm (A.CC0)When the multiturn limit set value is changed with parameter Pn205, a multiturn limit disagreement alarm(A.CC0) will be displayed because the value differs from that of the encoder.If this alarm is displayed, perform the operation described below and change the multiturn limit value in theencoder to the value set in Pn205.Factory Setting (= 65535) Other Setting (≠65535)+32767-32768 Motor rotations0RotationaldataReverseForward0Motor rotationsPn205 setting value ReverseForwardRotationaldataAlarmDisplay Alarm Name Alarm Code Output MeaningA.CC0 Multiturn Limit Dis-agreementALO1 ALO2 ALO3 Different multiturn limits have been set in theencoder and the multi-winding drive unit.ON (L) OFF (H) ON (L)Step Display afterOperation Keys Operation1 Press the MODE/SET Key to select the utility function.2 Press the UP or DOWN Key to select Fn013.3 Press the DATA/SHIFT Key for approximately one second."PGSEt" appears.4Press the MODE/SET Key. The value of the multiturn limitsetting in the absolute encoder will be the same as the valueof Pn205.When the setting is completed, "donE" flashes for approxi-mately one second.5 – Then, "donE" changes to "PGSEt".6 Press the DATA/SHIFT Key for approximately one second."Fn013" is displayed again.7 To enable the new setting, turn the control power supply OFF and ON again.MODE/SET DATA /MODE/SET DATA /MODE/SET DATA /MODE/SET DATA /MODE/SET DATA /