7.15 EasyFFT (Fn206)7-277 Utility Functions (Fn)7.15 EasyFFT (Fn206)EasyFFT sends a frequency waveform reference from the SERVOPACK to the servomotor and slightly rotatesthe servomotor several times over a certain period, thus causing machine vibration. The multi-winding driveunit detects the resonance frequency from the generated vibration and makes notch filter settings according tothe resonance frequency detection.. The notch filter is effective for the elimination of high-frequency vibrationand noise.Execute this function after the servo ON signal (/S-ON) is turned OFF if operation of the SERVOPACKresults in high-frequency vibration and noise.In addition to this function, online vibration monitor (Fn207) can be used to detect machine vibration andautomatically make notch filter settings.If a multi-winding drive unit is used to make adjustments, it is recommended that you use advanced autotun-ing. This built-in EasyFFT function is used to maintain interchangeability with previous models. There is nor-mally no need to use it.(1) PreparationThe following conditions must be met to perform EasyFFT.• The write prohibited setting parameter (Fn010) must be set to Write permitted (P.0000).• The main circuit power supply must be ON.• All alarms must be cleared.• The hardwire baseblock (HWBB) must be disabled.• The servo ON signal (/S-ON) must be OFF.• There must be no overtravel.• An external reference must not be input.WARNING• The servomotor rotates slightly when EasyFFT is executed. Do not touch the servomotor or machineduring execution of EasyFFT, otherwise injury may result.CAUTION• Use the EasyFFT when the servo gain is low, such as in the initial stage of servo adjustment. If EasyFFTis executed after increasing the gain, the servo system may vibrate depending on the machine character-istics or gain balance.Multi-windingdrive unitRotates the shaft slightlySlight movementSERVOPACKPeriodicwaveformreferenceResponse