4 Trial Operation4.6.3 Operating Procedure4-144.6.3 Operating ProcedureFollow the steps below to execute the test without motor using panel operator.Step Display after Operation Keys Description1 Press the MODE/SET Key to select the utility functionmode.2 Press the UP or DOWN Key to select the Pn00C.3 Press the DATA/SHIFT Key for approximately one sec-ond. The current data of Pn00C is displayed.4To enable the test without motor, press the UP Key tochange the setting from n.0 (factory setting) ton.1.n.0: Test without motor disabled.n.1: Test without motor enabled.5(Display blinks)Press the MODE/SET Key. The display began to blinkand the test without motor is enabled.6 Press the DATA/SHIFT Key once to select the first digitof the data.7Press the UP or DOWN Key to select the encoder resolu-tion.n.0 : 13 bit (factory setting)n.1 : 20 bit8(Display blinks)Press the MODE/SET Key. The display began to blinkand the encoder resolution is set to 20 bit.9 Press the DATA/SHIFT Key once to select the seconddigit of the data.10Press the UP or DOWN Key to select the encoder type.n.0 : incremental encoder (factory setting)n.1 : absolute encoder11 Press the MODE/SET Key. The display began to blinkand the incremental encoder is selected.12 To enable the change in the setting, turn the power OFF and ON again.MODE /SET DATA /MODE/SET DATA/MODE/SET DATA/MODE/SET DATA/MODE /SET DATA /MODE/SET DATA/MODE /SET DATA/MODE/SET DATA/MODE/SET DATA/MODE /SET DATA/MODE/SET DATA/