8 Monitor Modes (Un)8-48.3 Reading 32-bit Decimal DisplaysThis section describes how to read parameters displayed in 32-bit decimal on the Panel Operator.The method for reading the display is summarized below.The number of pulses between -2147483648 (-231 ) and 2147483647 (-2 31) is displayed continuously. Whenthe number of pulses is outside this range, the display will change as follows:• The displayed value will change to 2147483647 when the number of pulses decreases by one from-2147483648. Thereafter, the displayed value will decrease according to the number of pulses.• The displayed value will change to -2147483648 when the number of pulses increases by one from2147483647. Thereafter, the displayed value will increase according to the number of pulses.Step Display afterOperation Keys Operation1 Press the MODE/SET Key to select the monitor mode.2Press the UP or DOWN Key to display the parameter to bedisplayed in 32-bit decimal.In this example "Un00D" is selected.3Press the DATA/SHIFT Key for approximately one second.The lower 4 digits of the setting of the selected parameterare displayed.4After checking the displayed digits, press the DATA/SHIFTKey. The middle 4 digits of the setting of the selectedparameter are displayed.5Press the DATA/SHIFT Key again. The upper 2 digits of thesetting of the selected parameter are displayed.Note: If the DATA/SHIFT Key is pressed after the upper 2digits are displayed, the lower 4 digits of the settingwill be displayed again.6 Press the DATA/SHIFT Key for approximately one secondto return to the display of step 2.MODE /SET DATA /MODE/SET DATA/Lower 4 digitsMODE/SET DATA/Middle 4 digitsMODE/SET DATA/Upper 2 digitsMODE/SET DATA/MODE/SET DATA/Displays when negativenumber is displayedLeftmost blinks display shows digit'sposition. The digit's display and valuemeans parameter's value.Top two digits Middlefourdigits Bottomfour digits