2 Compatible Devices2.3.4 AC Reactor2-222.3.4 AC ReactorMake sure to install an AC reactor, which corresponds to the capacity of the individual power regenerationconverter, to each power regeneration converter.Do not connect any equipment other than the power regeneration converter to the secondary side of the ACreactor. If this caution is not observed, an overcurrent may occur in the power regeneration converter. An ACreactor is effective in improving the power factor of the power supply side.Select an AC reactor based on the following table. For details, refer to 5.2 AC Reactor.∗ This AC reactor does not comply with UL standards. If an AC reactor that complies with UL standards is required,contact your Yaskawa representative.2.3.5 Magnetic Contactor for Winding SelectionA magnetic contactor for winding selection is needed only if a winding selection motor is used as the spindlemotor.Select a magnetic contactor for winding selection based on the following table. For details, refer to 5.3 Mag-netic Contactor for Winding Selection.Power Regeneration Converter AC Reactor ModelInput Voltage ModelThree-phase,200 VACCACP-JU15A3 X008017CACP-JU19A3 X008018CACP-JU22A3 X008019CACP-JU30A3 X008020CACP-JU45A3B X008022Three-phase,400 VACCACP-JU15D3 X008010 *CACP-JU19D3 X008011CACP-JU22D3 X008012SERVOPACK for One Axis Magnetic Contactorfor Winding SelectionInput Voltage Model ModelStandard For UL Compliance270 VDCCACR-JU028ACAHV-75AP4 HV-75AP4/ULCACR-JU036ACACACR-JU065ACA540 VDCCACR-JU014DCACACR-JU018DCACACR-JU033DCA270 VDCCACR-JU084ACAHV-150AP4 HV-150AP4/ULCACR-JU102ACACACR-JU125ACA540 VDC CACR-JU042DCACACR-JU051DCA