4 Specifications and External Dimensions for Σ-V-SD Drivers4.1.2 External Dimensions4-44.1.2 External Dimensions(1) Model: CACP-JU153, -JU193, -JU223∗ The cooling air speed of heat sink must be at least 2.5 m/s at the point closest to the heat sink.(2) Model: CACP-JU30A3∗ The cooling air speed of heat sink must be at least 2.5 m/s at the point closest to the heat sink.Note: Available only for three-phase 200 VAC models.380Model NumberInput VoltageNameplate7.5(10)80100104-6 Dia.Ground Terminal2-M5 Screws(145) 300200Cooling Fan4-M5 Screw HolesPowerRegenerationConverterRear ViewThroughHole338365 ±0.580 ±(Mounting Pitch)380105 90100Mounting Hole Diagram(Mounting Pitch)7.536515.57.55(100)23867 (7) 334 (23)∗∗Air FlowAir Flow(115° )Unit: mmApprox. Mass: 8.3 kg(145) 300200Cooling FanHeat Sink5(100)23 334 (23)∗∗Air FlowAir Flow(115 ° )1367 (7)Unit: mmApprox. Mass: 11.1 kg380Model NumberInput Voltage7.5(10)130150104-6 Dia.Ground Terminal2-M6 Screws7.5365NameplatePowerRegenerationConverterRear View4-M5 Screw Holes(Mounting Pitch)380338365±0.5ThroughHole130±0.5105 140150Mounting Hole Diagram(Mounting Pitch)15.57.5