5.3 Magnetic Contactor for Winding Selection5-9 Peripheral Devices55.3 Magnetic Contactor for Winding Selection5.3.1 Specifications∗1. Safety covers are provided on the HV- AP4S and HV- AP4S/UL.∗2. A dwell time of 1 hour or more is required after applying power supply for 30 minutes.5.3.2 External DimensionsThe external dimensions are shown below.(1) Model: HV-75AP4Model*1 Standard HV-75AP4 HV-150AP4For UL Compliance HV-75AP4/UL HV-150AP4/ULContact Main contact: 3NO, 3NC, auxiliary contact: 1NCRated Insulation Voltage 600 VRated Applying Current Continuous 75 A 150 A30 minutes*2 87 A 175 ABreaking CurrentCapacity220 V 200 A 400 A440 V 150 A 300 AOpen/Close Frequency 600 times/hourMechanical Duration of Life 5 million timesControl Magnetic Coil Rating 200 V 50/60 Hz, 220 V 50/60 Hz,230 V 60 HzMass 2.5 kg 5.0 kgAmbient Temperature -10 to 55°CStorage Temperature -20 to 85°CHumidity 10 to 95%RH (non-condensing)Spindle Motor Capacity (50%ED) 5.5 to 15 kW 18.5 to 30 kWMain circuit terminals (M5)Control circuit terminals (M4)4-M6 mounting holesUnit: mm1 2 3 4 5 67 8 9 10 11 1213 1415 1617 18145160107928565110