CSX7000 Guide14 CyberSWITCHThe group numbers correspond to the number of systems configured on the backplane. You mayneed to reset this value (i.e., enter Autoconfiguration Mode) due to a change in your backplanesegmentation. To do so, perform the following:• Power down the CSX7000.• Power up the CSX7000. Press and hold the BC Group “select up” button during the first 5 sec-onds of the initial power-up cycle.The BC Group numbers will then reset per the current backplane configuration.M ULTIPORT B OARD / MP S ERIAL P ORT PUSH BUTTONSThese four remaining push buttons (in the group of six) are not used with the CSX7000.G ROUP P OWER SWITCHThe selected group may have the power turned on or off via the recessed GROUP POWER switchon the front panel. This power on/off function is operational only for the specific group selected(with BC GROUP push buttons) and only if the console is unlocked. This switch allows you to turnoff a specific group for maintenance purposes while other groups continue to operate.BC RESET S WITCHIndividual groups may be reset using the BC RESET switch. The BC RESET switch is recessed toprevent accidental resets. This reset function is operational only for the specific group selected (withBC GROUP push buttons), and only if the console is unlocked.WARNING:Even though BC RESET is available, we do not recommend its use with the CyberSWITCHsystem groups. We recommend individual power on/off cycles to ensure proper systemreset/restart.AUDIBLE CLEAR SWITCHAUDIBLE CLEAR is a recessed push-button switch. It is used to clear an environmental alarm onlyif an audible alarm is enabled by BCVision.When an environmental parameter exceeds its system limits, the environmental alert LED displaysan amber light, and an audible alarm sounds. This alarm continues to sound until theenvironmental parameter again falls within system limits, or the AUDIBLE CLEAR switch ispressed.