COPYRIGHT © 2001 CANON INC. 2000 2000 2000 2000 CANON iR8500/7200 REV.1 AUG. 2001CHAPTER 2 NEW FUNCTIONS2-672) Insert the pins of the mirror positioningtool (front [2]/rear [3]) into each of theholes [1]: No. 1 mirror base, No. 2 mir-ror base, and rail. The position of theNo. 2 mirror base is adjusted by slidingthe cable fixing plate to the front andthe rear.F02-309-17F02-309-183) Secure the end of the cable so far tem-porarily fixed to the hook of the readerframe using a spring.4) Fully tighten the screw on the cable fix-ing plate.5) Fully tighten the cable metal fixing onthe No. 1 mirror base.6) Detach the mirror positioning tool.7) Reverse steps 1) through 6) for mount-ing.[2][1][3][1]