COPYRIGHT © 2001 CANON INC. 2000 2000 2000 2000 CANON iR8500/7200 REV.1 AUG. 2001ERROR CODEE-19E506Main cause A fault occurs in downloading to the flash ROM built into the slave CPU(IC125).Condition0001 A fault occurs in the serial communication for data transmission.0002 A fault occurs in write operation to the flash memory (write opera-tion fails).0003 A fault occurs in transferring the user program (checksum mis-match).0004 A fault occurs in transferring the slave program (checksum mis-match).0005 After a shift to download mode, 3 mins passes without any opera-tion. Or, the machine is started up without completing download-ing.E510Main cause The inlet motor (M1) is faulty. The finisher controller PCB is faulty.Condition00FF When the motor is in operation, the clocks from the inlet motor in-dicates 50 mm/sec less for 1 sec or more.E514Main cause The stack delivery motor (M7) is faulty. The stack delivery motor clocksensor (PI12) is faulty. The finisher controller PCB is faulty.Condition00FF When the motor is in operation, the clock signals from the stackdelivery motor clock sensor indicate 50 mm /sec or less for 1 sec.