COPYRIGHT © 2001 CANON INC. 2000 2000 2000 2000 CANON iR8500/7200 REV.1 AUG. 2001ERROR CODEE-33E713Main cause The connector has poor connection. The finisher accessory power supplyPCB is faulty. The finisher controller PCB is faulty. The DC controller PCBis faulty.Condition0000 The communication IC (IPC) on the finisher controller PCB is outof order.E717Main cause The wiring is faulty (short circuit, open circuit). The copy data controller orthe NE controller is faulty. The main controller PCB is faulty.Condition0000 The copy data controller or the NE controller is out of order, or thewiring has an open circuit.Caution You must clear the error in service mode: COPIER>FUNCTION>CLEAR>ERR.E719Main cause The wiring is faulty (short circuit, open circuit). The coin vendor is faulty.The main controller PCB is faulty.Condition0002 The communication between the coin vendor and the main control-ler PCB is interrupted.Caution You must clear the error in service mode: COPIER>FUNCTION>CLEAR>ERR.E732Main cause The cable connector has poor connection. The reader controller PCB isfaulty.Condition0001 The main controller PCB detects a fault in the communication be-tween the reader controller PCB and the main controller PCB.