COPYRIGHT © 2001 CANON INC. 2000 2000 2000 2000 CANON iR8500/7200 REV.1 AUG. 2001ERROR CODEE-13E243(iR7200)Main Cause The control panel CPU PCB is faulty. The main controller PCB is faulty.Condition0000 An error has occurred in communication between the CPU of thecontrol panel CPU PCB and the main controller PCB.E248(Indicated if iR7200)Main Cause The EEPROM on the reader controller PCB is faulty. The reader controllerPCB is faulty.Condition0001 The ID read into the EEPROM when the main power switch hasbeen turned on and the ID in the ROM do not match.0002 When data is written into EEPROM, the data written and the dataread do not match.0003 When data is written, the ID in the EEPROM and the ID in theROM are found not to match.E251(Indicated if iR8500)Main cause The inverter cooling fan (FM9) is faulty. The wiring is faulty (short circuit,open circuit). The reader controller PCB is faulty.Condition0000 The lock signal (FM9LCK) arrives for 5 secs or more although theinverter cooling fan (FM9) is driven.E302(iR8500)Main cause The CCD/AP PCB is faulty. The wiring is faulty (short circuit, open cir-cuit). The reader controller PCB is faulty.Condition0000 During shading operation, shading processing does not end on thereader controller PCB.