COPYRIGHT © 2001 CANON INC. 2000 2000 2000 2000 CANON iR8500/7200 REV.1 AUG. 2001CHAPTER 4 INSTALLATION4-42 Unpacking and Installation (iR8500 Series)2.1 Points to Note Before Starting the Installation WorkGo through the following before starting the installation work:1. Moving a machine from a cold to warm place can cause condensation (inthe from of droplets of water on its metal surfaces).A machine surffering from condensation can produce image faults. If themachine has just been brought in from a cold place, leave it alone (un-packed) for at least 1 hour or before starting the work.2. If the machine is moved into or out of the user’s along stairs, observe thefollwing:a. Remove the ADF, fixing/feeding unit, holding tray assembly, and copypaper, and carry them separately from the machin.b. When lifting the machine, do not grab the grips on the pickup/deliveryassembly; rather, hold it by its four bottom corners.3. Shift up the two adjusters (front) on the bottom of the machine to makesure that they are unlocked. Further, take care not to lose the adjusters,which can slip off the bottom because of vibration occuring in transit.4. Work in a group of three or more. Particularly, when removing the pad,assign one person to work at the rear and one at the front, with one re-moving the pad.5. Remove the side paper deck or the finisher (options) to prevent damegewhen bringing in or out the machine.