COPYRIGHT © 2001 CANON INC. 2000 2000 2000 2000 CANON iR8500/7200 REV.1 AUG. 2001ERROR CODEE-11E220(iR8500)Main cause The fluorescent lamp activation is faulty. The light adjustment sensor isfaulty. The light adjustment control PCB is faulty. The inverter PCB isfaulty. The reader controller PCB is faulty.Condition0000 The fluorescent lamp does not reach a specific intensity within 10secs after it is turned on (if the room temperature is 10°C or lower,within 60 secs). Or, the activation detection signal (FL-DTCT)does not go OFF within 5 secs after the fluorescent lamp is turnedoff; during shading adjustment, the activation detection signal (FL-DTCT) does not go ON within 60 secs after the fluorescent lamp isturned on.E220(iR7200)Main Cause The lamp inverter PCB is faulty. The reader controller PCB is faulty.Condition0001 The lamp inverter PCB is found to have a fault.E222(Indicated if iR8500)Main cause The lamp heater (H5) is faulty. The light adjustment control PCB is faulty.The reader controller PCB is faulty. The wiring is faulty (short circuit, opencircuit).Condition0000 During initial activation after power-on, the heater does not reach70°C within 5 mins after it is turned on. Or, during standby orreading, the heater does not reach 75°C within 3 mins after it isturned on.