– integer: a value from 1 to 65,535 that identifies the RMON group of statistics. The value must be a unique index in theRMON History Table.– owner: (Optional) specifies the name of the owner of the RMON group of statistics. The default is a null-terminated string.– ownername: (Optional) records the name of the owner of the RMON group of statistics.– buckets: (Optional) specifies the maximum number of buckets desired for the RMON collection history group of statistics.– bucket-number: (Optional) a value associated with the number of buckets specified for the RMON collection historygroup of statistics. The value is limited to from 1 to 1000. The default is 50 (as defined in RFC-2819).– interval: (Optional) specifies the number of seconds in each polling cycle.– seconds: (Optional) the number of seconds in each polling cycle. The value is ranged from 5 to 3,600 (Seconds). Thedefault is 1,800 (as defined in RFC-2819).Example of the rmon collection history CommandTo remove a specified RMON history group of statistics collection, use the no form of this command.The following command example enables an RMON MIB collection history group of statistics with an ID number of 20 and an ownerof john, both the sampling interval and the number of buckets use their respective defaults.Dell(conf-if-mgmt)#rmon collection history controlEntry 20 owner johnRemote Monitoring (RMON) 725