v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See Chapter 3, “Parts listing, System x3200 M2 Types 4367 and 4368,” on page 33 to determine whichcomponents are customer replaceable units (CRU) and which components are field replaceable units(FRU).v If an action step is preceded by “(Trained service technician only),” that step must be performed only by atrained service technician.Error code Description Action175 Service processor flash code damaged ornot loaded. 1. Update the Remote Supervisor Adapter IISlimLine firmware.2. Replace the Remote Supervisor Adapter IISlimLine.178 Security hardware error. 1. Run the Configuration/Setup Utility program,select Load Default Settings, and save thesettings.2. (Trained service technician only) Replace thesystem board.184 Power-on password damaged. 1. Run the Configuration/Setup Utility program,select Load Default Settings, and save thesettings.2. Reseat the battery.3. Clear CMOS. See “System-board jumpers” onpage 13 for information about how to clearCMOS.4. Replace the following components one at a time,in the order shown, restarting the server eachtime:a. Batteryb. (Trained service technician only) Systemboard187 VPD serial number not set. 1. Set the serial number by updating the BIOS codelevel (see “Updating the firmware” on page 15).2. (Trained service technician only) Replace thesystem board.188 Service processor firmware corrupted or notinstalled. 1. Restart the server.2. Run the Configuration/Setup Utility program,select Load Default Settings, and save thesettings.3. Update the Remote Supervisor Adapter IISlimLine firmware (see“Updating the firmware” onpage 15).4. (Trained service technician only) Replace thesystem board.189 Three attempts were made to access theserver with an incorrect password.Restart the server and enter the administratorpassword; then, run the Configuration/Setup Utilityprogram and change the power-on password.289 A DIMM has been disabled by system. 1. Make sure that the DIMM is installed correctly(see “Installing a memory module” on page 76).2. Replace the DIMM.3. (Trained service technician only) Replace thesystem board.Chapter 5. Diagnostics 129