v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See Chapter 3, “Parts listing, System x3200 M2 Types 4367 and 4368,” on page 33 to determine whichcomponents are customer replaceable units (CRU) and which components are field replaceable units(FRU).v If an action step is preceded by “(Trained service technician only),” that step must be performed only by atrained service technician.System-error log message ActionSystem is over recommended voltage for +3.3V 1. Reseat the following components:a. Hot-swap power supplies, if any are installedb. Power supply cables on the system board2. (Trained service technician only) Replace the system board.System is over recommended voltage for 1.5VCPU 1. Reseat the following components:a. Hot-swap power supplies, if any are installedb. Power supply cables on the system board2. (Trained service technician only) Replace the system board.System is over recommended voltage on VRM (Trained service technician only) Reseat the microprocessor.System is under recommended voltage for+3.3V 1. Reseat the following components:a. Hot-swap power supplies, if any are installedb. Power supply cables on the system board2. (Trained service technician only) Replace the system board.System is under recommended voltage for 1.5VCPU 1. Reseat the following components:a. Hot-swap power supplies, if any are installedb. Power supply cables on the system board2. (Trained service technician only) Replace the system board.System is under recommended voltage on VRM (Trained service technician only) Reseat the microprocessor.System log 75% full Clear the current logs.System log cleared Information only.System Memory Error 1. Reseat the DIMMs.2. Replace the DIMMs.System over recommended voltage for +12V 1. Reseat the following components:a. Hot-swap power supplies, if any are installedb. Power supply cables on the system board2. (Trained service technician only) Replace the system board.System over recommended voltage on +2.5V 1. Reseat the following components:a. Hot-swap power supplies, if any are installedb. Power supply cables on the system board2. (Trained service technician only) Replace the system board.System over recommended voltage oncontinuous +5V 1. Reseat the following components:a. Hot-swap power supplies, if any are installedb. Power supply cables on the system board2. (Trained service technician only) Replace the system board.Chapter 5. Diagnostics 223