v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See Chapter 3, “Parts listing, System x3200 M2 Types 4367 and 4368,” on page 33 to determine whichcomponents are customer replaceable units (CRU) and which components are field replaceable units(FRU).v If an action step is preceded by “(Trained service technician only),” that step must be performed only by atrained service technician.Error code Description Action1762 Hard disk drive configuration error. 1. Run the Configuration/Setup Utility program andload the default settings.2. Reseat the following components:a. Hard disk drive cablesb. Hard disk drivec. (Trained service technician only) Systemboard3. Replace the following components one at a time,in the order shown, restarting the server eachtime.a. Hard disk drive cablesb. Hard disk drivec. (Trained service technician only) Systemboard178x Fixed disk error.Note: x is the drive that has the error. 1. Run the hard disk drive diagnostic tests on drivex.2. Reseat the following components, depending onthe server model:v Hot-swap models:a. Hard disk drive xb. SAS/SATA controllerv Simple-swap models:a. Hard disk drive xb. Hard disk drive x cable3. Replace the following components one at a time,depending on the server model, in the ordershown, restarting the server each time:v Hot-swap models:a. Hard disk drive xb. Hard disk drive backplanec. SAS/SATA controllerv Simple-swap models:a. Hard disk drive xb. Hard disk drive x cable4. (Trained service technician only) Replace thesystem board.1800 Unavailable PCI hardware interrupt. 1. Run the Configuration/Setup Utility program andadjust the adapter settings.2. Remove each adapter one at a time, restartingthe server each time, until the failing adapter isisolated.Chapter 5. Diagnostics 131