v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See Chapter 3, “Parts listing, System x3200 M2 Types 4367 and 4368,” on page 33 to determine whichcomponents are customer replaceable units (CRU) and which components are field replaceable units(FRU).v If an action step is preceded by “(Trained service technician only),” that step must be performed only by atrained service technician.Error code Description Action1801 A PCI adapter has requested memoryresources that are not available. 1. Make sure that no devices have been disabled inthe Configuration/Setup Utility program.2. Change the order of the adapters in the PCI, andPCI Express slots. Make sure that the startup(boot) device is positioned early in the scanningorder. (For information about the scanning order,see the User’s Guide on the IBM System xDocumentation CD).3. Make sure that the settings for the adapter and allother adapters in the Configuration/Setup Utilityprogram are correct. If the memory resourcesettings are not correct, change them.4. If all memory resources are being used, removean adapter to make memory available to theadapter. Disabling the BIOS on the adaptershould correct the error. See the documentationthat comes with the adapter.1802 No more I/O space is available for a PCIadapter. 1. If the error code indicates a particular PCI orPCI-E slot or device, remove that device.2. Reseat each adapter.3. Replace the following components one at a time,in the order shown, restarting the server eachtime:a. Failing PCI or PCI Express adapterb. (Trained service technician only) Systemboard1803 No more memory (above 1 MB for a PCIadapter). 1. If the error code indicates a particular PCI orPCI-E slot or device, remove that device.2. Reseat each adapter.3. Replace the following components one at a time,in the order shown, restarting the server eachtime:a. Failing PCI or PCI Express adapterb. (Trained service technician only) Systemboard1804 No more memory (below 1 MB for a PCIadapter). 1. Remove the failing adapter.2. Reseat each adapter.3. Replace the following components one at a time,in the order shown, restarting the server eachtime:a. Failing PCI or PCI Express adapterb. (Trained service technician only) Systemboard132 System x3200 M2 Types 4367 and 4368: Problem Determination and Service Guide