Version: 1.01 Field Programming Reference (FPRG) 617 PROGRAM MENUYou can modify the test and other configuration data byKPG-91D.Figure 7-3 “Test Mode” windowNote:! The cooling Fan is switched On operates in PC Test Mode.! Refer to the Service Manual for checking how to test.7.3.1 Test ChannelIt can select the channel to test. You can select thenumbers of the channel configured on the “TestFrequency” window by the spin buttons. (Refer to 6.13Test Frequency Window.)The frequency configured to the selected channel numberappears on the “Frequency” window.Note: You cannot select the number of the channel that is notconfigured on the “Test Frequency” window.7.3.2 Test SignallingIt can select the test signalling. Select the number of thetest signalling that is already configured by the spinbuttons.The Decode Tone/Encode Tone configured to theselected signalling Number appears on the “Frequency”window.signalling No.: signalling No. of the Test ModeDecode Tone: Reception signallingEncode Tone: Transmission signallingTable 7-1 Test SignallingNote: TKR-750/850/751/851 deactivates AF Mute when thesignalling is decoded with the QT/DQT code and thesignalling matches.Range 1 - 16Default 1Range Test signalling No. 1 - 16Default 1signallingNo. Decode tone Encode tone1 None None2 None 100 Hz square wave3 QT 67.0 Hz QT 67.0 Hz4 QT 151.4 Hz QT 151.4 Hz5 QT 210.7 Hz QT 210.7 Hz6 QT 250.3 Hz QT 250.3 Hz7 DQT D023N DQT D023N8 DQT D754I DQT D754I9 None CW ID Encode [ID = VVV]10 None Single Tone [1000 Hz]11 DTMF 159D DTMF 159D12 None DTMF Tone 913 None Courtesy Tone*1*1: The value configured in the “Optional Features 2" tab. (Refer to6.4.2 Optional Features 2 Tab.)14 None Battery Warning Tone*115 None Battery Operation Tone*116 - -