Manual PD4-C (USB)12 Object directory descriptionVersion: 1.4.1 / 22.07.2016 / FIR-v1626 1022034h Upper Voltage Warning LevelFunctionThis object holds the threshold level for the "Overvoltage" error in millivolts.Object descriptionIndex 2034hObject Name Upper Voltage Warning LevelObject Code VARIABLEData type UNSIGNED32Saveable yes, category: applicationAccess Read/writePDO Mapping NoAdmissible ValuesSpecified Value • : 00006590h• PD4-C5918M4204-E-01: 0000C92Ch• PD4-C6018L4204-E-01: 0000C92Ch• PD4-CB59M024035-E-01: 00007530h• PD4-C5918L4204-E-01: 0000C92Ch• PD4-C5918M4204-KSAR2: 0000C92ChFirmware Version FIR-v1426Change HistoryDescriptionIf the input voltage of the motor controller rises above this threshold value, the motor is switched offand an error is output. This error is automatically reset when the input voltage is less than (voltage ofthe object 2034h minus 2 volts).2035h Lower Voltage Warning LevelFunctionThis object holds the threshold level for the "Undervoltage" error in millivolts.Object descriptionIndex 2035hObject Name Lower Voltage Warning LevelObject Code VARIABLEData type UNSIGNED32Saveable yes, category: applicationAccess Read/writePDO Mapping NoAdmissible ValuesSpecified Value 00002710hFirmware Version FIR-v1426Change History