Provisioning the ELAN subnet 57ATTENTIONWhen you type the customer number in the overlays, ensure that it is the correctcustomer number.Provisioning the ELAN subnetIntroductionDefine and configure the ELAN subnet for the AML link and its associatedVSID in the configuration record. This provides the Ethernet connectionover which AML messages are exchanged between the CS 1000 systemand CallPilot.To provision the ELAN subnetStep Action1 Load overlay 17.2 For each prompt listed below, type the response indicated. Forthose prompts that are not listed, you can accept the default bypressing Enter.Prompt Response DescriptionREQ CHG ChangeTYPE ADAN Action device and numberADAN NEW ELAN xx Configure a new link and assign it anumber, where xx is within the ELANsubnet range (16-31). You can useany number in this range as long as itis not already used.CTYP ELAN Card typeDES x...x type a designator to identify this ELANsubnet.REQ CHG ChangeTYPE VAS Value added server configurationVAS new Configure a new AML link or changethe existing link configuration.VSID yy The VAS identifier can be in the rangeof 16-31. For convenience, this canbe the same number you assignedto the new ELAN subnet link (inresponse to the ADAN prompt).ELAN xx This should be the same numberdefined in ADAN.Nortel CallPilotCommunication Server 1000 and CallPilot Server ConfigurationNN44200-312 01.02 Standard5.0 3 May 2007Copyright © 2007, Nortel Networks.