Maintenance- 338 -Replacing the paper feed roller (Tray2/3/4)For the replacement cycle, see "Paper feed roller (P.327)".This section takes for example the procedure of replacing the paper feed roller of Tray2. You can replace thepaper feed roller of Tray3/4 by following the same procedure. Please replace the paper feed roller with clean hands. If hand oil or hand cream gets on the rubber part, the paperfeed function may deteriorate. For the procedure of replacing the paper feed roller of Tray1, refer to "Replacing the paper feed roller (Tray1)(P.334)".1 Prepare a new feed roller assembly for Tray1/2/3/4 and check that you have all the parts.Separation rollerPaper feed roller (without gear)Paper feed roller (with gear)2 Pull out the paper cassette of Tray 2 by holding its handle until it stops, raise the paper cassettea little by holding its both sides, and take it out.If you pull out the paper cassette with the power on, "Change settings?" may appear on the display. Thismessage will disappear automatically in 10 seconds after the paper cassette is returned to the main unit.