- 131 -8.92 ^MF MEDIA FEEDFormat: ^MFp,hp = Feed action at power-upF : Feed ([ESC] T command)L : Feed (no sensor adjustment)N : No actionC : CalibrationS : Calibration (short)Default: "POWER ON CALIB" in the Z-MODE parameterWhen omitted: This command is ignored.h = Feed action after head is closedF : Feed ([ESC] T command)L : Feed (no sensor adjustment)N : No actionC : CalibrationS : Calibration (short)Default: "HEAD CLOSE CALIB" in the Z-MODE parameterWhen omitted: This command is ignored.*1 Operations such as “feed” and “calibration” are not performed with this command.*2 This command specifies the operation to be or not to be performed after “power ON” and “headclose.*3 The value is restored to the previous setting by turning off/on the unit.*4 If either of the setting for parameter p or h is omitted, this command is ignored.*5 Calibration after power-up• When C or S is selected, LE840/LE850 standard calibration is performed. When L or F isselected, feed operation is performed for the set label pitch. When N is selected, nooperation is performed.• When C or S is selected and calibration is performed, the label length, the sensor selection,and the ribbon selection cannot be modified with the command.*6 Calibration after head close• When C or S is selected, LE840/LE850 standard calibration is performed. When L or F isselected, feed operation is performed for the set label pitch. (Note that, after printing with aselected sensor, feed to the print start position is performed.) When N is selected, nooperation is performed.• When C or S is selected and calibration is performed, the label length, the sensor selection,and the ribbon selection cannot be modified with the command.*7: When the media length is specified with the shorter pitch than the actual one, and also when FEEDis selected for this parameter, a feed jam may occur depending on the media stop position.When FEED is selected, set an appropriate pitch.