- 35 -correspondence with the “Font Conversion Table.”Since the information in the “Font Change Table” is exclusive for ^CW, it cannot be used here.*3 If the font name is improper or omitted, set the font type with the following procedure:In the case the font name is omitted:If a valid font name is already set with A@ command, the font previously printed with A@command is used. If a valid font name is not specified in A@ command, the font specifiedin CF command is used.In the case the font name is improper:If a valid font name is already set with A@ command, Font 0 is used. If a valid font nameis not specified in A@ command, the font specified in CF command is used.8.3 ^B2 INTERLEAVED 2 OF 5 BAR CODEFormat: ^B2o,h,f,g,eo = Font rotationN : 0°R : 90°I : 180°B : 270°When omitted: Value of ^FW* The point of origin differs depending on the coordinate designated in ^FT and ^FO.h = Bar code height (in dots)203-dpi printer: LE8401 to 800 dots300-dpi printer: LE8501 to 1200 dotsWhen omitted: Value of ^BY*1 If the value after dot-to-mm conversion exceeds 100 mm, it is corrected to 100 mm.*2 If 0, a character string, or other value is selected, it is corrected to 10 dots.f = Print interpretation lineY : PrintedN : Not printedWhen omitted: Yg = Print interpretation line above codeY : PrintedN : Not printedWhen omitted: Ne = Calculate and print Modulus 10 check digitY : PrintedN : Not printedWhen omitted: N*1 Data other than numeric values, if any, will be deleted.*2 When data are set with ^SN and the parameter z of ^SN (add leading zeros) is N, ‘0’ at thebeginning of data will be deleted.*3 To print the interpretation line above code, the interpretation line parameter (parameter f) needs tobe set to “Y.”*4 The character type of the interpretation line is independent of the module width value of ^BY. Font