7.1 Utility—Diagnosis7.1.1 Utility—Diagnosis—Card DiagnosisPerforms diagnostic tests on cards installed in the PBX, to identify the source of problems.If any of the tests listed here returns the result "NG" ("No Good"), contact your dealer.When testing is complete, any cards that were set to OUS status must be returned to INS status if they are tobe used again.This screen can be accessed only in On-line mode.Card TestTests the relevant functions of a card to ensure that it is operating correctly. The tests carried out vary accordingto the type of card being tested.The tests that are performed on each card are listed below.Test Type Available CardsLocal loop back diagnosis DLC2, DLC8, DLC16, LCOT6 (Pre-installed/Option), BRI2, BRI4,PRI23, PRI30/E1DTMF Receive test port DHLC4, MCSCL8, MCSLC16 (Pre-installed/Option)PT loop back diagnosis DLC2, DLC8, DLC16, DHLC4To perform a card test1. Click on the Status cell of the card to be tested, and set it to "OUS".2. Click on the cell showing the card type.A new window will be displayed.3. Select the Card Test option, and then click Execute.The error report will be displayed. When all tests are completed, the words "Test End!" will be shown onthe last line of the output.4. Select an option:• Click Capture if you want to save the displayed information.1. Specify a save destination and file name.2. Click Save.• Click Cancel to return to the Diagnosis screen.NoteTo run consecutive card tests on the BRI2/BRI4 card, you must change the card’s status to INS, thenOUS again after running each test.104 PC Programming Manual7.1.1 Utility—Diagnosis—Card Diagnosis