12.1 PBX Configuration—[4-1] Extension—WiredExtension12.1.1 PBX Configuration—[4-1-1] Extension—WiredExtension—Extension SettingsFor each slot in which an extension card is installed, a certain number of extension ports are displayed. Foreach extension port, various extension settings can be assigned.To search for a specific extension, enter the extension number or the extension name in the search box andclick Find Next.To copy the settings of an extension to another extension, click Copy to. The copied data includes FWD/DND,personal speed dialling, and flexible button settings.To assign a set of CLIP numbers automatically, click CLIP Generate.The Shelf, Slot, and Port for each item are displayed for your reference. For details, see CommonProgramming Reference Items in 9.1 PBX Configuration—[1-1] Configuration—Slot.MainExtension NumberSpecifies the extension number of the extension.Value RangeMax. 5 digits (consisting of 0–9)Extension NameSpecifies the name of the extension.Value RangeMax. 20 charactersPort TypeIndicates the extension port type (reference only).Value RangeDPT: DPT port (DLC)SLT: SLT port (MCSLC)S-Hybrid: Super Hybrid port (DHLC)S-Hybrid(SLT): XDP port of Super Hybrid port (DHLC)S-Hybrid(S-DPT): Digital XDP port of Super Hybrid port (DHLC)DPT(S-DPT): Digital XDP port of DPT port (DLC)ISDN: ISDN port (BRI/PRI)IP-EXT: IP-Extension port (V-IPEXT)SIP: General SIP Extension port (V-SIPEXT)SIP-MLT: KX-UT series SIP phone/S-PS/SIP-CS Extension port (V-UTEXT)UM: Unified Messaging System Extension port558 PC Programming Manual12.1.1 PBX Configuration—[4-1-1] Extension—Wired Extension—Extension Settings