4–Non-Interactive CommandsCommand SummarySN0054614-00 K4-21#scli-kl(<hbainstance> |<hbawwpn>)To do a loopback test with customized parameters, type:#scli-kl(<hbainstance> |<hbawwpn>)[(<paramname>|<paramalias>)<paramvalue>]Where:Sections “DataPattern (DP)” on page 4-21 through “LoopbackType (LT)” onpage 4-24 describe how to change the default parameters for both of these tests.“Run a Loopback Test” on page 4-24 contains command line examples and testresults for a loopback test. “Run a Read/Write Buffer Test” on page 4-28 containscommand line examples and test results for a read/write buffer test.DataPattern (DP)For the loopback test, the data pattern is either:DPvalue>DataPatternvalue>hba instance= Adapter number (use-gcommand to find)hba wwpn= World wide port name of the adapter-exor-exclude= World wide port name of the target device to beexcluded from the read/write testparam name= One of the following:DataPattern (see “DataPattern (DP)” on page 4-21)DataSize (see “DataSize (DS)” on page 4-23)TestCount (see “TestCount (TC)” on page 4-23)TestIncrement (see “TestIncrement (TI)” onpage 4-23)OnError (see “OnError (OE)” on page 4-24)LoopbackType (see “LoopbackType (LT)” onpage 4-24)param alias= One of the following:DP (see “DataPattern (DP)” on page 4-21)DS (see “DataSize (DS)” on page 4-23)TC (see “TestCount (TC)” on page 4-23)TI (see “TestIncrement (TI)” on page 4-23)OE (see “OnError (OE)” on page 4-24)LT (see “LoopbackType (LT)” on page 4-24)param value= Value for selected parameter