4–Non-Interactive CommandsCommand SummarySN0054614-00 K 4-31If the read/write buffer test fails, the system shows the following information: Loop/port ID (the loop ID of the adapter when operating in loop mode). Status: Success—The test passed. Error—A data miscompare or link status firmware error occurred. Failed—A link status error, SCSI write buffer error, or SCSI read buffererror occurred. Unknown—The target was not present. Unsupported—The device does not support this test. Data Miscompare—The possible values are: 0 (no data miscompares) Device not present Get link status failed Read buffer failed R/W buffer not supported Write buffer failedc Compliant jitter tolerance pattern in a FC frame, as defined by the ASIC document listed above.d Compliant supply noise test sequence in a valid FC frame, as defined by the ASIC document listed above.e For read/write buffer test, the maximum size is 128; this is also the default. For an echo test, the maximum size is2048; the default size is 512. For a loopback test on Windows, Solaris, and Macintosh systems, the maximum size is2048; the default size is 512. For a loopback test on Linux OSs, the maximum size is 65535; the default size is 512.f 0=test continuously. 1–10,000 and 1–65535=total number of tests that will be executed.g Must be less than the TestCount value.Table 4-12. Data Pattern (DP) Test PatternsHex Binary00 0000000055 010101015A 01011010A5 10100101AA 10101010FF 11111111