3029PROGRAMMING ACCOUNT CODESThis program is used to add or change account code entries.PROGRAM KEYSKEYPAD - Used to enter the account code (allowable digits 0–9).UP & DOWN - Used to select entry number.FLASH & TRSF - Used to view and change only the used entries.SPK/RLS - Used to clear data.Open customer programming and follow the instructions below.ACTION DISPLAY1. Press TRSF and then dial 708 ACCOUNT CODEDisplay shows (001)2. Dial the account code entry (e.g., 005) ACCOUNT CODEOR press UP or DOWN to select the (005)entry number and press the right softkey to move the cursor3. Enter the account code via the dial pad, ACCOUNT CODEe.g., 1234 (maximum of 12 digits) and (005)123456789012press the right soft key to move thecursor back to step 24. Press TRSF to store and exit pro-gramming OR press SPK to store andadvance to the next programSTATION TIMERSEach station can have five timers customized for them to accommodate stationusers with individual work habits. These timers are as follows:NO ANS FWD No Answer ForwardThis is the amount of time a call will ring at a station before it forwards to theForward No Answer destination. The default is 15 seconds and the range is 000 to250 seconds. Make sure that this timer is not set to a greater value than the trans-fer recall timer or transferred calls will not forward.DTMF DUR. DTMF DurationThis is the duration of DTMF tones sent to an analog voice mail port. The defaultduration is 100 milliseconds and the range is 0100 to 9900 milliseconds.F-DGT DELY First Digit DelayThis is the time the system will wait before sending DTMF digits to a voice mailport. The default time is 600 milliseconds and the range is from 100 to 9900 mil-liseconds.OFFHK SEL. Off Hook SelectThis timer controls the delay between going off hook (lifting the handset) and theoff hook select destination being called.The default duration is 10 seconds and therange is from 000 to 250 seconds.EFWD DELAY External Forward DelayThis is the time that a station will ring before a call forwards to the external call for-ward destination. The default duration is 10 seconds and the range is 1 second to250 seconds.Open customer programming and follow the instructions below.PROGRAM KEYSKEYPAD - Used to set timer values.UP & DOWN - Used to select extension number.SPK/RLS - Save data and advance to next program.ACTION DISPLAY1. Press TRSF and then dial 502 [201] NO ANS FWDDisplay shows 010 SEC