Reverse Print Command (Create)171Reverse Print Command (Create)This command allows you to define an area on a form where reverse printing(white ouput on black background) will be output.Reverse printing cannot be used with OCR Characters or Overlay Data.Table 15. Reverse CommandField Function Option/Modifier SelectionsREVERSE This is the command specifier.Using the following parameters afield of reverse printing will bedefined for a location on a form.Enter REVERSED;Dark PrintingOptional parameter for changinghorizontal dot density from 60 DPIto 120 DPI.Enter D; or DARK; to select this option.The SR, SC, ER, and EC parameters use the same methods for defining the REVERSE Printarea. Whether in columns or dots depends on the SCALE Command. You may also use theXX.YY format for plotting duplication print locations explained earlier in the Standards Section.SR; Plots the starting ROW of the field. Enter a value ranging from 1 to one lessthan the maximum form length and thedelimiter.SC; Plots the starting COLUMN of thefield.Enter a value ranging from 1 to one lessthan the maximum form width and thedelimiter.ER; Plots the ending ROW of the field.The ending row must be greaterthan the starting row.Enter a range ranging from 2 to one lessthan the maximum form length and thedelimiter.EC Plots the ending COLUMN of thefield. The ending column must begreater than the starting column.Enter a value ranging from 2 to themaximum form width.STOP Command Terminator. Enter STOP and the printer waits for a newcommand. Leave it out and the printer willwait for another REVERSE Command.